Skip to content

BridgeBottomRight1

Position within a bridge tile set of the piece that closes an east-west span at its bottom-right end.

Specification
Applies to
tile controls
File
theater control file
Section
[General]
Value
integer
When omitted
-1The position lands two tiles before the set's first piece rather than on a piece of it.

This is where an eastward repair stops. The repair steps a cell at a time from the top-left end, or from a middle piece at subtile 5, restoring middle sections as it goes, and finishes when it meets a cell at this position showing subtile 4; a walk that has not met one within twenty-nine cells returns without laying the bridge deck back down. A collapse walks the same way but stops at the first bridge cell it meets, whether an end at this position or a middle section. BridgeMiddle1 covers how a position is measured.

An end piece has no condition ladder of its own. It is marked whole or damaged instead, and the mark is carried to every neighboring cell drawn from the same piece.